Lamp Test and Lamp StatusThis is a great reactor
modification that interfaces with the CXE Control Console. The excerpt below is from the “Help” manual that is available on the CXE console screen. This not only describes the Lamp Status option, it also demonstrates the versatility of the software. Module and Lamp AnimationEach Lamp Module and Lamp is represented as an animation. If an individual lamp has been reported as good, that lamp will have a “Pass” remark inside it. In addition, if a lamp has a current passing to it above the detection level, it will be represented in a bright red color. If a lamp has no current passing to it or is below the detection level, it will be represented in a dark red color. In addition, if during an Auto Lamp Test or during a process run, a lamp is determined to be bad, the color of the lamp will turn to a gray color and have a “Fail” remark inside it. TZ, CZ, BZ Test SPThese Setpoints are used for two purposes. First, during an Auto IR Lamp Test they act as the Percent power output used during the lamp test. In addition, the same setpoints are used during an auto process run as the “trip point” that the IR Lamp Detect circuits will start looking for failed lamps. During an Auto IR Lamp Test,
the lamps will be checked once every 6 seconds for a lamp fail indication
after the During an Auto Process, the lamps will be checked after a 1 ½ minute delay for SCR Pack Soft Start and then if the % power to each individual zone % power setpoint is equal to or above the zone test setpoint mentioned above. When both these conditions are met, the lamps will be checked and reported once every 6 seconds. Start Auto IR Lamp TestSelecting this button starts an auto IR Lamp Test cycle. After Selecting this button, all the lamps will be reset to a “Pass” status and the Lamp test will start. The button at this time will change to “Stop Auto IR Lamp Test” during the lamp test cycle. Selecting this button during a lamp test cycle will stop the lamp test cycle. All lamps will indicate a “Pass” status due to the Lamp test being terminated prior to the end of its normal cycle. Lamp Test AlarmingSelecting Enable activates the display and actions listed below in “Lamp Test Fail Indications”. Selecting Disable inhibits all warnings and alarms listed. Lamp Test Fail Indications
|
CXE
Equipment Services, LLC
100 Zachary Road | Manchester, NH 03109 TEL (603) 606-5411 | FAX (603)606-5911 Email: sales@cxe-equip.com |